Perpustakaan Terpadu Poltekkes Kemenkes Malang
🇮🇩 ID | 🇬🇧 EN

Karya Ilmiah Mahasiswa

Jelajahi koleksi Karya Tulis Ilmiah (KTI) mahasiswa Poltekkes Kemenkes Malang.

Kembali ke Daftar KTI
Cover KTI
tidak tersedia
2023

ANALISIS BAKTERI COLIFORM PADA LIMBAH AIR AKHIR INSTALASI PENGOLAHAN AIR LIMBAH (IPAL) KOMUNAL DI JANTI BARAT PEDEPOKAN KOTA MALANG

Penulis: FARIZA GILANG SALSABILA
NIM: P17120201010
Program Studi: D3 ANALISIS FARMASI DAN MAKANAN
Dosen Pembimbing: Apt. M. Hasan Wattiheluw, S. Farm., M. Farm.
Tahun: 2023
Tanggal Pengesahan: 2023-05-19
Kode KTI: 9300_610 SAL a-1 SAL a
Subjek: IPAL Komunal, Total Coliform, MPN
Kata Kunci: IPAL Komunal, Total Coliform, MPN
Bahasa: INDONESIA

Abstraksi

Usaha pemerintah berbasis masyarakat untuk mengatasi pencemaran limbah rumah tangga dilakukan dengan pendiriaan program Instalasi Pengolahan Air Limbah (IPAL) yang dipergunakan secara komunal. Air limbah yang berasal dari aktivitas rumah tangga umumnya mengandung bahan-bahan atau zat-zat yang sangat membahayakan kesehatan manusia dan mengganggu lingkungan hidup. Efektifitas kerja IPAL Komunal dapat dilihat salah satunya pada parameter biologi yaitu total Coliform. Menurut Permen LHK No. 68 tahun 2016, kadar maksimum total Coliform pada baku mutu air limbah dosmetik sebesar 3.000/100 ml. Penelitian ini bertujuan untuk mengetahui apakah limbah air akhir hasil pengolahan IPAL Komunal di Janti Barat Padepokan, Kota Malang teridentifikasi mengandung bakteri Coliform dan nilai total Coliform telah memenuhi baku mutu, sehingga air limbah hasil pengolahan aman untuk dialirkan ke badan sungai. Parameter total Coliform pada sampel air dianalisis menggunakan metode Most Probable Number (MPN) dengan 2 tahap pengujian yaitu uji penduga dilakukan untuk mengetahui keberadaan bakteri Coliform dan dilanjutkan dengan uji penegasan atau uji konfirmasi yang berfungsi untuk mengkonfirmasi keberadaan bakteri Coliform dalam tabung yang positif. Hasil analisis menunjukkan bahwa kedua sampel limbah air akhir Instalasi Pengolahan Air Limbah (IPAL) Komunal di Janti Barat Padepokan, teridentifikasi mengandung bakteri Coliform dengan nilai MPN sebesar >160.000/100 ml untuk S1 dan hasil yang sama diperoleh oleh S2 yaitu dengan nilai MPN >160.000/100 ml yang artinya melewati batas cemaran dan standar baku mutu menurut Peraturan Menteri Lingkungan Hidup dan Kehutanan Nomor P.68 /Menlhk/ Setjen/ Kum.1/8/2016 Tahun 2016 tentang Baku Mutu Air Limbah Domestik. Kata kunci : IPAL Komunal, Total Coliform, MPN

Abstract (English)

Community-based government efforts to overcome household waste pollution are carried out by establishing a Wastewater Treatment Plant (WWTP) program that is used communally. Waste water originating from household activities generally contains materials or substances that are very harmful to human health and disrupt the environment. The effectiveness of the work of the Communal WWTP can be seen in one of the biological parameters, namely totalColiform. According to Minister of Environment and Forestry No. 68 of 2016, maximum total conten tColiform in the domestic waste water quality standard of 3,000/100 ml. This study aims to determine whether the final wastewater from the treatment of the Communal WWTP in Janti Barat Padepokan, Malang City is identified as containing bacteria. Coliform and total value Coliform has met the quality standards, so that the treated wastewater is safe to flow into river. The total Coliform parameters in the water samples were analyzed using the Most Probable Number (MPN) method with 2 stages, namely a prediction test which was carried out to determine the presence of Coliform bacteria and followed by an affirmation test or confirmation test which functioned to confirm the presence of Coliform bacteria in the positive tube. The results of the analysis showed that the two samples of wastewater from the Communal Wastewater Treatment Plant (IPAL) in Janti Barat Padepokan were identified as containing bacteria. The total Coliform with an MPN value of >160,000/100 ml for S1 and the same result was obtained for S2, namely with an MPN value of >160,000/100 ml, which means that it has exceeded the contamination limit and quality standards according to the Regulation of the Minister of Environment and Forestry Number P.68 /Menlhk/ Setjen/ Kum.1/8/2016 of 2016 concerning Domestic Wastewater Quality Standards. Keywords: Communal WWTP, Total Coliform, MPN
Akses berkas KTI mengikuti ketentuan perpustakaan. Tautan dokumen tidak ditampilkan sampai lokasi penyimpanan dan kebijakan hak_akses dikonfirmasi.
Chatbot Perpustakaan
📚

Perpustakaan Digital

Poltekkes Kemenkes Malang

Halo 👋

Selamat datang di layanan digital perpustakaan.

Sistem ini membantu pencarian informasi perpustakaan secara cepat dan otomatis.

Contoh pertanyaan:
• cara menjadi anggota perpustakaan
• cara cek plagiarisme
• Jam buka perpustakaan